UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

A comparison of similarity measures for use in 2-D-3-D medical image registration

Penney, GP; Weese, J; Little, JA; Desmedt, P; Hill, DL; Hawkes, DJ; (1998) A comparison of similarity measures for use in 2-D-3-D medical image registration. IEEE TRANS MED IMAGING , 17 (278-0062) pp. 586-595.

Full text not available from this repository.

Abstract

A comparison of six similarity measures for use in intensity-based two-dimensional-three-dimensional (2-D-3-D) image registration is presented. The accuracy of the similarity measures are compared to a "gold-standard" registration which has been accurately calculated using fiducial markers. The similarity measures are used to register a computed tomography (CT) scan of a spine phantom to a fluoroscopy image of the phantom. The registration is carried out within a region-of-interest in the fluoroscopy image which is user defined to contain a single vertebra. Many of the problems involved in this type of registration are caused by features which were not modeled by a phantom image alone. More realistic "gold-standard" data sets were simulated using the phantom image with clinical image features overlaid. Results show that the introduction of soft-tissue structures and interventional instruments into the phantom image can have a large effect on the performance of some similarity measures previously applied to 2-D-3-D image registration. Two measures were able to register accurately and robustly even when soft-tissue structures and interventional instruments were present as differences between the images. These measures were pattern intensity and gradient difference. Their registration accuracy, for all the rigid-body parameters except for the source to film translation, was within a root-mean-square (rms) error of 0.54 mm or degrees to the "gold-standard" values. No failures occurred while registering using these measures

Type: Article
Title: A comparison of similarity measures for use in 2-D-3-D medical image registration
Additional information: DA - 19990210
Keywords: Algorithms, Comparative Study, Fluoroscopy, Humans, Phantoms, Imaging, Research Support, Non-U.S.Gov't, Spine, radiography, Tomography, X-Ray Computed
UCL classification: UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: http://discovery.ucl.ac.uk/id/eprint/157882
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only