In the UK, the Standard Assessment Procedure (SAP) is used to rate the energy performance of existing dwellings whenever they are let or sold. This study investigates which of the inputs to SAP account for the most variance in energy rating across existing gas central heated houses in England. Data from the English Housing Survey (EHS) 2009 are used to generate a representative set of dwellings and variance-based global sensitivity analysis is then applied to assess each input’s contribution to the variance in the calculated ratings. It is demonstrated that heating system efficiency, external wall U-value and dwelling geometry account for 75% of the variance of the energy rating of gas central heated houses in England. This suggests that improving heating system efficiencies and wall U-values of the worst performing dwellings will go a long way towards improving their energy rating and potentially reducing their energy consumption. It is also demonstrated that dwelling geometry has a much bigger influence on the calculated carbon emissions (accounting for 80% of the variance) than it does on the SAP energy rating (accounting for 30%), meaning that significant improvements in energy rating might not be accompanied by significant reductions in carbon emissions.

Type: Article
Title: Key factors determining the energy rating of existing English houses
Open access status: An open access version is available from UCL Discovery
DOI: 10.1080/09613218.2014.905383
Publisher version: http://dx.doi.org/10.1080/09613218.2014.905383
Language: English
Additional information: © 2014 The Author(s). Published by Taylor & Francis. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/ licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The moral rights of the named author(s) have been asserted.
Keywords: building stock, energy rating, global sensitivity analysis, household energy, housing stock, modelling, Standard Assessment Procedure (SAP)
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment > Bartlett School Env, Energy and Resources
URI: https://discovery.ucl.ac.uk/id/eprint/1428865
Downloads since deposit
621Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item