UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Randomized Trial Comparing the Effectiveness of 2 Electric Breast Pumps in the NICU.

Burton, P; Kennedy, K; Ahluwalia, JS; Nicholl, R; Lucas, A; Fewtrell, MS; (2013) Randomized Trial Comparing the Effectiveness of 2 Electric Breast Pumps in the NICU. J Hum Lact , 29 (3) pp. 412-419. 10.1177/0890334413490995. Green open access

[thumbnail of J_Hum_Lact-2013-Burton-412-9.pdf]
Preview
PDF
J_Hum_Lact-2013-Burton-412-9.pdf

Download (867kB)

Abstract

Background:Mothers with preterm infants may need to express milk for considerable periods. Research to improve breast pump design has focused on compression stimuli, frequencies, and vacuums.Objective:This study aimed to compare the effectiveness of 2 electric pumps: Medela Symphony (pump S) and a novel pump (Philips AVENT Twin electronic pump; pump A). Both offer flexibility of rate and suction; pump A also incorporates petal compression cushions. Primary outcomes were (1) milk weight expressed during 10-day study period and (2) weight of milk expressed in a 15-minute test.Methods:Seventy-one mothers with preterm infants < 34 weeks were randomized. Mothers completed 10-day diaries including weight of milk expressed. Milk weight expressed during a single 15-minute test period and data on pumping mode, skin-to-skin contact, breastfeeding at infant discharge, and mothers' opinions of the pump were recorded.Results:There was no significant difference in milk expressed during the first 10 days between groups. Pump S mothers expressed significantly more milk during a fixed 15-minute period. Mothers using pump A awarded higher scores for certain characteristics of the pump, notably location of control button and ease of use. Similar proportions of infants received breast milk at discharge, but pump A mothers were more likely to be directly breastfeeding (odds ratio, 4.27 [95% confidence interval, 1.29, 14.1]).Conclusion:The breast pumps showed similar effectiveness in terms of milk expression and maternal opinions. The finding that breast pump design may influence breastfeeding at infant discharge merits further investigation.

Type: Article
Title: Randomized Trial Comparing the Effectiveness of 2 Electric Breast Pumps in the NICU.
Open access status: An open access version is available from UCL Discovery
DOI: 10.1177/0890334413490995
Publisher version: http://dx.doi.org/10.1177/0890334413490995
Additional information: © The Author(s) 2013. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(http://www.uk.sagepub.com/aboutus/openaccess.htm).
Keywords: breast pump, breastfeeding, clinical efficacy, mechanical efficacy, milk expression, milk volume, neonatal unit
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health > Population, Policy and Practice Dept
URI: https://discovery.ucl.ac.uk/id/eprint/1400949
Downloads since deposit
309Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item