Use of the intravascular contrast agent NC100150 Injection in spin echo and gradient echo imaging of the heart

Taylor, AM; Panting, JR; Keegan, J; Gatehouse, PD; Jhooti, P; Yang, GZ; ... Pennell, DJ; + view all (1999) Use of the intravascular contrast agent NC100150 Injection in spin echo and gradient echo imaging of the heart. Journal of Cardiovascular Magnetic Resonance , 1 (1) 23 - 32. Green and gold open access

[img]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
931Kb

Abstract

This is the first study of the intravascular iron oxide particle contrast agent, NC100150 Injection (Nycomed Imaging AS, Oslo, Norway, a part of Nycomed Amersham) in magnetic resonance imaging of the human heart. Eighteen healthy male volunteers were studied at both 0.5 and 1.5 T before and after the administration of NC100150 Injection. Transaxial spin-echo images were acquired at both field strengths, conventional gradient-echo cine images at 0.5 T, and breathhold Turbo-FLASH cine images at 1.5 T. Optimized cine imaging sequences were used postcontrast, with a high flip angle of 60-70”. In the spin-echo images there was a significant reduction in the blood pool flow artifact at the level of the right atrium (0.5 T, 57%, p < 0.01; 1.5 41%. p = 0.01) and the left ventricle (LV) (0.5 T, 45%, p = 0.01; 1.5 T, 45%, p < 0.01). In the conventional gradient-echo cines at 0.5 T, there was a significant increase in the LV blood pool and myocardial signal difference-to-noise ratio (SDNR) in the diastolic (56%, p = 0.01) and systolic (141%, p < 0.OOl)frames. There was also a significant increase in the signal intensity (SI) gradient at the LV blood pool-myocardial border in the diastolic and systolicframes (both p < 0.001). At higher doses of NClOO150 Injection (3 and 4 mg/kg), a rim of signal void around the LV blood pool was observed, perfectly defining the LV blood pool- myocardial border. In the Turbo-FLASH breathhold cines at 1.5 T, there was a significant increase in the LV blood pool-myocardial SDNR in the diastolic (221%, p < 0.001) and systolic (916%, p < 0.001) frames. Again, there was also a significant increase in the SI gradient at the LV blood pool- myocardial border in the diastolic and systolicframes (both p = 0.003). In conclusion, NC100150 Injection was given safely to 18 healthy subjects. Image quality and LV blood pool-myocardial definition were improved after the administration of NClOOI50 Injection. These improvements enable better spin-echo anatomical defiition, better definition of myocardial wall motion, and should improve the capability of automated edge detection algorithms.

Type:Article
Title:Use of the intravascular contrast agent NC100150 Injection in spin echo and gradient echo imaging of the heart
Identifier:PMID: 11550338
Open access status:An open access publication. A version is also available from UCL Discovery.
Publisher version:http://www.scmr.org/Education/journal/JCMR_past_issues.html#1999
Language:English
Additional information:Authors are the copyright holders of their articles and have granted to any third party, in advance and in perpetuity, the right to use, reproduce or disseminate the article.
Keywords:Cardiac MR; Contrast agents; Intravascular; iron-oxide particles
UCL classification:UCL > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science