Honarbakhsh, S; Schilling, RJ; Providência, R; Dhillon, G; Sawhney, V; Martin, CA; Keating, E; ... Hunter, RJ; + view all (2017) Panoramic atrial mapping with basket catheters: A quantitative analysis to optimize practice, patient selection, and catheter choice. Journal of Cardiovascular Electrophysiology , 28 (12) pp. 1423-1432. 10.1111/jce.13331. Green open access

[thumbnail of Bebiano Da Providencia E Costa_Sherry Panoramic.pdf]
Preview
Text
Bebiano Da Providencia E Costa_Sherry Panoramic.pdf - Accepted Version

Download (337kB) | Preview

Abstract

INTRODUCTION: Panoramic mapping with basket catheters has been used to map atrial fibrillation (AF). However, the limited tissue contact and coverage achieved has raised concerns. METHODS AND RESULTS: Patients undergoing catheter ablation for atrial tachycardia (AT) and persistent AF were recruited. Unipolar signals were recorded with the Constellation or FIRMap catheters. The proportion and distribution of anatomical coverage by the catheters was determined and tissue contact achieved measured. The impact of catheter position, left atrium (LA) size, and bipolar voltage were evaluated. Forty patients were recruited (20 Constellation and 20 FIRMap). The LA coverage achieved with the FIRMap catheter compared to the Constellation catheter was greater (76.9 ± 12.9% vs. 50.8 ± 10.3%; P < 0.001), with better septal coverage (66.8 ± 20.9% vs. 15.5 ± 12.0%; P < 0.001). A greater number of electrodes recorded peak-to-peak electrogram amplitude of ≥0.5 mV (84.2% vs. 62.8%; P < 0.001). Positioning the catheter tip at or posterior to LA appendage ridge gave better coverage than a more anterior position (P = 0.001). Increasing LA area correlated inversely with coverage (P < 0.001) and contact (P = 0.002) despite patient-specific basket catheter sizing. An LA area of >30 cm2 and mean bipolar voltage of <0.3 mV was associated with reduction in coverage and contact (both P < 0.001). There was a significant difference in AT/AF freedom during follow-up in the FIRMap versus Constellation group (13/13 vs. 8/12; P = 0.04). CONCLUSIONS: The FIRMap is superior to the Constellation catheter in terms of LA coverage and contact. Optimizing catheter position and appropriate patient selection based on no more than moderately dilated or scarred atria will also facilitate mapping with basket catheters.

Type: Article
Title: Panoramic atrial mapping with basket catheters: A quantitative analysis to optimize practice, patient selection, and catheter choice
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1111/jce.13331
Publisher version: http://doi.org/10.1111/jce.13331
Language: English
Additional information: atrial fibrillation, atrial tachyarrhythmia, basket catheters, catheter ablation, panoramic atrial mapping
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Health Informatics
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10057441
Downloads since deposit
419Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item