UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain

Ianuş, A; Jespersen, SN; Duarte, TS; Alexander, DC; Drobnjak, I; Shemesh, N; (2018) Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain. NeuroImage , 183 pp. 934-949. 10.1016/j.neuroimage.2018.08.034. (In press). Green open access

[thumbnail of c7ob03138f__.pdf]
Preview
Text
c7ob03138f__.pdf - Accepted Version

Download (7MB) | Preview

Abstract

Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for mapping μA, usually using measurements from a single b shell. However, the accuracy of μA estimation vis-à-vis different b-values was not assessed. Moreover, the time-dependence of this metric, which could offer additional insights into tissue microstructure, has not been studied so far. Here, we investigate both these concepts using theory, simulation, and experiments performed at 16.4T in the mouse brain, ex-vivo. In the first part, simulations and experimental results show that the conventional estimation of microscopic anisotropy from the difference of D(O)DE sequences with parallel and orthogonal gradient directions yields values that highly depend on the choice of b-value. To mitigate this undesirable bias, we propose a multi-shell approach that harnesses a polynomial fit of the signal difference up to third order terms in b-value. In simulations, this approach yields more accurate μA metrics, which are similar to the ground-truth values. The second part of this work uses the proposed multi-shell method to estimate the time/frequency dependence of μA. The data shows either an increase or no change in μA with frequency depending on the region of interest, both in white and gray matter. When comparing the experimental results with simulations, it emerges that simple geometric models such as infinite cylinders with either negligible or finite radii cannot replicate the measured trend, and more complex models, which, for example, incorporate structure along the fibre direction are required. Thus, measuring the time dependence of microscopic anisotropy can provide valuable information for characterizing tissue microstructure.

Type: Article
Title: Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.neuroimage.2018.08.034
Publisher version: http://dx.doi.org/10.1016/j.neuroimage.2018.08.034
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Diffusion MRI, Double diffusion encoding, Microscopic anisotropy, Microstructure imaging, Oscillating gradients
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/10055633
Downloads since deposit
144Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item